Fiber optic cable is the foundation of every broadband, telecom, and utility network being built today. From loose tube OSP backbone to last-mile drops and air-blown microduct cable, Galloway stocks OSP fiber from OFS, Prysmian, and AFL - the manufacturers whose names are on the spec sheets your engineers submit. We hold inventory across our regional locations so your build schedule doesn’t wait on cable.

Galloway_Fiber_Reels_T2
Reels in the Yard Greenfield OH SML

Loose Tube - OSP Backbone, Feeder & Distribution

Fujikura Ribbon Fiber Splicing kit 6-22-26-8090 Medium

Color-coded loose buffer tubes

Protect individual fibers from mechanical and environmental stress; stranded designs carry 6 to 24 tubes, central-tube designs a single tube

More information chevron_right

Single-mode OS2 (G.652.D) standard, G.657.A1 for tighter bend routing;

OFS AllWave ZWP fiber gives zero water peak across the full wavelength spectrum

Gel-free DryBlock construction (OFS)

Reduces splice prep time by up to 80% vs. gel-filled designs

Jacket and construction options span single jacket (SJ) through double-armored (DA)

Corrugated steel tape armor for direct-burial without conduit or in rodent-prone areas; OFS Fortex DT Light Armor is gel-free and mass-fusion-ready

All-dielectric ADSS variant for aerial self-support

No messenger wire, no grounding on energized power lines; aramid strength members support spans to ~1,500 m depending on loading; OFS PowerGuide DT double-jacket eliminates all gels

Fiber counts from 12 to 864

Standard reel lengths 1 km and 2 km; multimode OM3/OM4 available for campus and data center interconnect

Loose Tube - OSP Backbone, Feeder & Distribution

Fujikura Ribbon Fiber Splicing kit 6-22-26-8090 Medium

noimage-3

Color-coded loose buffer tubes

Color-coded loose buffer tubes protect individual fibers from mechanical and environmental stress; stranded designs carry 6 to 24 tubes, central-tube designs a single tube

Single-mode OS2 (G.652.D)

Single-mode OS2 (G.652.D) standard, G.657.A1 for tighter bend routing; OFS AllWave ZWP fiber gives zero water peak across the full wavelength spectrum

Gel-free DryBlock construction (OFS)

Gel-free DryBlock construction (OFS) reduces splice prep time by up to 80% vs. gel-filled designs

Jacket and construction options span single jacket (SJ)

Jacket and construction options span single jacket (SJ) through double-armored (DA): corrugated steel tape armor for direct-burial without conduit or in rodent-prone areas; OFS Fortex DT Light Armor is gel-free and mass-fusion-ready

All-dielectric ADSS

All-dielectric ADSS variant for aerial self-support---no messenger wire, no grounding on energized power lines; aramid strength members support spans to ~1,500 m depending on loading; OFS PowerGuide DT double-jacket eliminates all gels

Fiber counts from 12 to 864

Fiber counts from 12 to 864; standard reel lengths 1 km and 2 km; multimode OM3/OM4 available for campus and data center interconnect

Ribbon - High Fiber Count Backbone & Trunk

Fujikura Ribbon Fiber Splicing kit 6-22-26-8089 Medium

 

  • For high-density backbone and trunk, hyperscale data center interconnect, and central office / carrier-hotel cabling

  • Fiber counts from 144 to 6,912+; outside diameter is critical for duct-fill calculations

  • Standard matrix, rollable, and intermittently bonded ribbon (IBR) constructions; rollable / IBR allows higher packing density in a smaller diameter

  • 12-fiber mass-fusion splicing dramatically reduces splice time vs. single-fiber splicing

  • Single jacket, double jacket, armored, or all-dielectric construction

Loose Tube - OSP Backbone, Feeder & Distribution

  • bookmark_check
    Color-coded loose buffer tubes protect individual fibers from mechanical and environmental stress; stranded designs carry 6 to 24 tubes, central-tube designs a single tube
  • bookmark_check
    Single-mode OS2 (G.652.D) standard, G.657.A1 for tighter bend routing; OFS AllWave ZWP fiber gives zero water peak across the full wavelength spectrum
  • bookmark_check
    Gel-free DryBlock construction (OFS) reduces splice prep time by up to 80% vs. gel-filled designs
  • bookmark_check
    Jacket and construction options span single jacket (SJ) through double-armored (DA): corrugated steel tape armor for direct-burial without conduit or in rodent-prone areas; OFS Fortex DT Light Armor is gel-free and mass-fusion-ready
  • bookmark_check
    All-dielectric ADSS variant for aerial self-support---no messenger wire, no grounding on energized power lines; aramid strength members support spans to ~1,500 m depending on loading; OFS PowerGuide DT double-jacket eliminates all gels
  • bookmark_check
    Fiber counts from 12 to 864; standard reel lengths 1 km and 2 km; multimode OM3/OM4 available for campus and data center interconnect
Galloway_Single_Mode_OS2_Fiber

Ribbon - High Fiber Count Backbone & Trunk

  • bookmark_check
    For high-density backbone and trunk, hyperscale data center interconnect, and central office / carrier-hotel cabling
  • bookmark_check
    Fiber counts from 144 to 6,912+; outside diameter is critical for duct-fill calculations
  • bookmark_check
    Standard matrix, rollable, and intermittently bonded ribbon (IBR) constructions; rollable / IBR allows higher packing density in a smaller diameter
  • bookmark_check
    12-fiber mass-fusion splicing dramatically reduces splice time vs. single-fiber splicing
  • bookmark_check
    Single jacket, double jacket, armored, or all-dielectric construction
Galloway_High_Fiber_Count_2

Flat Drop - Last-Mile FTTH

  • bookmark_check
    Flat self-supporting design for last-mile drops to home or business---aerial self-support or direct-buried final span
  • bookmark_check
    1, 2, 4, 6, and 12-fiber counts; G.657.A2 bend-tolerant fiber typical; compatible with standard wedge clamps and closure strain reliefs
  • bookmark_check
    Toneable (copper toner) variant locates buried drops after install without digging; all-dielectric version also available
  • bookmark_check
    MDPE outdoor jacket with flame-retardant option for indoor transition; pre-connectorized (OptiTap / hardened) or bulk reel; RUS (RDUS)-listed options available
Galloway_Last_Mile_2

Drop - Subscriber & MDU

  • bookmark_check
    Round and figure-8 subscriber drops for aerial, buried, and MDU riser applications; indoor pulls behind walls, conduit, or risers

  • bookmark_check
    1, 2, 4, and 12-fiber counts; field-terminated or factory-connectorized installs

  • bookmark_check
    Riser (OFNR) and plenum (OFNP) rated jackets for inside-building portions

  • bookmark_check
    Pre-connectorized options---OptiTap, hardened MPO, SC/APC; check bend-radius rating for tight retrofit pulls; compliant with ANSI/ICEA, Telcordia, and IEC standards

Galloway_Drop_Cable

Micro - Air-Blown / Microduct Cable

  • bookmark_check
    High-density FTTH and FTTx distribution installed by air-blowing or pushing into pre-placed microducts---ideal for retrofits, congested ROW, and rapid deployment

  • bookmark_check
    Reduced outside diameter (4 to 10 mm) is the key differentiator; fiber counts 12 to 432, and 864+ in larger ODs

  • bookmark_check
    Low-friction HDPE jacket for blown install; all-dielectric construction with water-blocking via dry tape / SAP yarns

  • bookmark_check
    [TBC] Microduct ID compatibility (e.g., 8.5 / 12.7 mm), maximum recommended blowing distance, and installed / dynamic bend radius

Galloway_Air_Blown_Microduct

Flat Drop - Last-Mile FTTH

  • Flat self-supporting design for last-mile drops to home or business---aerial self-support or direct-buried final span

  • 1, 2, 4, 6, and 12-fiber counts; G.657.A2 bend-tolerant fiber typical; compatible with standard wedge clamps and closure strain reliefs

  • Toneable (copper toner) variant locates buried drops after install without digging; all-dielectric version also available

  • MDPE outdoor jacket with flame-retardant option for indoor transition; pre-connectorized (OptiTap / hardened) or bulk reel; RUS (RDUS)-listed options available

Features

Makes gradual bends without special equipment, reducing labor time and installation costs makes gradual bends without special equipment, reducing labor time and installation costs

  • check_circle
    check_circle

    Manufactured from flexible HDPE

    makes gradual bends without special equipment, reducing labor time and installation costs

  • check_circle
    check_circle

    Continuous reel lengths

    minimize joints in the field, meaning fewer couplings, fewer potential failure points, and faster installation

  • check_circle
    check_circle

    Sunlight resistant

    rated for outdoor exposed applications without additional UV protection

  • check_circle
    check_circle

    Temprature

    Rated for use with 90°C conductors at a maximum ambient temperature of 122°F (50°C)

  • check_circle
    check_circle

    Nonconductive

    eliminates the need for grounding of the raceway itself and prevents conduit from becoming an electrical hazard

  • check_circle
    check_circle

    Corrosion resistant

    will not rust, rot, or degrade in wet, acidic, or alkaline soil conditions where metal conduit deteriorates

  • check_circle
    check_circle

    Lightweight

    approximately one-third the weight of steel conduit, reducing handling labor and transportation costs

  • check_circle
    check_circle

    Assembled with PVC solvent cement

    for fast, permanent joints—no threading, welding, or special tools required

Cable Type Selection & Specification Guide

Cable Type Primary Applications Tube Count Fiber Counts Outside Diameter Jacket Types Specs to confirm before ordering
Loose Tube (a.k.a. Stranded LT, Central LT / CLT, Armored LT) OSP backbone, feeder, and distribution
Long-haul trunk between handholes and vaults
Aerial lashed, in-duct, direct-buried
6–24 (stranded design)
1 (central tube)
12 to 864 8–25 mm SJ – single jacket
DJ – double jacket
SA – single armored
DA – double armored
AD – all-dielectric
Fiber type — G.652.D standard, G.657.A1 for tighter bends
Water-blocking — gel-filled vs. dry / water-swellable tape
Install method — duct, direct-buried, or lashed aerial
Strand attach — separate messenger vs. self-supporting (ADSS)
Reel length and put-up
Ribbon (a.k.a. Standard Matrix Ribbon, Rollable Ribbon, IBR) High fiber count backbone and trunk
Hyperscale data center interconnect
Central office and carrier-hotel cabling
1 central (RCLT)
6–8 stranded (RILT)
144 to 6,912+ 12–35 mm SJ – single jacket
DJ – double jacket
SA – armored
AD – all-dielectric
Ribbon type — standard matrix vs. rollable / IBR
Outside diameter critical for duct-fill calculations
Mass-fusion splicer compatibility on the project
Blown-installation rating if applicable
Reel length and put-up
Flat Drop (a.k.a. Toneable Flat Drop, AD Flat Drop, Figure-8 Flat) Last-mile FTTH drops to home or business
Aerial self-support or direct-buried final span
Toneable variant locates buried drops post-install
— (no buffer tubes) 1, 2, 4, 6, 12 ~4.5 × 8.1 mm or 4.5 × 10.2 mm (W × H) SJ – MDPE outdoor
Flame-retardant for indoor transition
Toneable (copper toner) vs. all-dielectric
Aerial self-support vs. direct-buried rating
Pre-connectorized (OptiTap / hardened) vs. bulk reel
Fiber type — G.657.A2 typical
Length / cut-to-order requirements
Jacket color for service marking
Drop (a.k.a. Figure-8 Drop, Round Drop, Indoor/Outdoor Drop, MDU Drop) Subscriber drops — aerial, buried, MDU riser
Field-terminated or factory-connectorized installs
Indoor pulls behind walls, conduit, or risers
1 or tight-buffered 1, 2, 4, 12 4–10 mm (round)
Figure-8 varies
SJ – outdoor MDPE
OFNR – riser rated
OFNP – plenum rated
Form factor — figure-8, round, or flat
Pre-connectorized type — OptiTap, hardened MPO, SC/APC
Riser or plenum rating for inside-building portions
Length / cut-to-order requirements
Bend radius rating for tight retrofit pulls
Micro (a.k.a. Microduct Cable, Blown Cable, Reduced-OD Cable, Mini-LT) High-density FTTH and FTTx distribution
Air-blown or push installation into pre-placed microducts
Retrofits, congested ROW, rapid deployment
1–12 (varies by fiber count) 12 to 432
(864+ in larger ODs)
4–10 mm SJ – low-friction HDPE for blown install
AD – all-dielectric construction
Microduct ID compatibility (e.g., 8.5 / 12.7 mm)
Blown vs. push installation rating and shot length
Fiber count and construction (loose tube vs. ribbon)
Maximum recommended blowing distance
Bend radius — installed and dynamic
Water-blocking via dry tape / SAP yarn (dielectric)

Jacket Code Reference: SJ Single Jacket • DJ Double Jacket • SA Single Armored • DA Double Armored • AD All-Dielectric • OFNR Riser-Rated • OFNP Plenum-Rated

Proposed expanded cable-type guide (per restructure). Fiber-count, OD, and jacket ranges are manufacturer-typical and must be confirmed against stocked products before publication. See notes below.

Technical Specifications

Specification Standard Stocked Range Standard Stocked Range
Standard Stocked Range Standard Stocked Range

Material

High-Density Polyethylene (HDPE)

 

 

 

Available Sizes

3/4” through 6” diameter

 

 

 

SDR Options

SDR 7, 9, 11, 13.5, 15.5 (controlled by outside diameter and minimum wall thickness)

 

 

 

SIDR Options

SIDR 9, 11.5 (controlled by inside diameter and minimum wall thickness)

 

 

 

Schedule Options

Schedule 40 and Schedule 80

 

 

 

Standards Compliance

ASTM D3035, ASTM D2239, ASTM F2160

 

 

 

Listings

RUS Listed for telecommunications applications

 

 

 

Pull Tape

Available empty or with factory pre-installed pull tape (1,250 lb typical tensile strength)

 

 

 

Standard Colors

Orange, blue, green, black, white, red, brown, gray, terra cotta, yellow. Custom colors and stripe combinations available.

 

 

 

Reel Sizes

66”, 84”, 96”, 102”, 114” diameter steel reels

 

 

 

Conduit Markings

Permanent marking includes material type, applicable standards, production information, and sequential foot/meter markings. Custom marking available.

 

 

 

Eyebrow

Title would go here

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Quisque hendrerit purus ex, eget molestie quam rutrum vitae. In egestas faucibus magna, vel malesuada mi tempor a. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Quisque hendrerit purus ex, eget molestie quam rutrum vitae. In egestas faucibus magna, vel malesuada mi tempor a.

Brands we carry

Need Fiber Cable for Your Build?

Galloway stocks fiber optic cable across our distribution network, keeping material positioned close to your jobsite. Whether you have defined specifications or need assistance selecting the right cable for your installation, our team can help ensure the right product is supplied and delivered.

At Galloway, we don’t wait for a spec sheet. Talk us through the job and we’ll make sure you get what you need.

Galloway_Fiber_Install

Talk to a local specialist

Fort Myers, FL
(239) 481-7448
Tampa, FL
(813) 443-5598
Miami, FL
(786) 378-4615
New Castle, DE
(302)-317-1502
Columbus, OH
(614) 414-0861
Greenfield, IN
(317) 947-6271
Parker, CO
(720) 683-6100
Phoenix, AZ
(623) 738-2800
Tyler, TX
(430) 341-0010
Chesapeake, VA
(757) 263-0159